Concrete
Heavy and rigid. Check seams, lids and shell condition.
Installation and replacement both need an approved design. A larger tank cannot make unsuitable soil work.
Florida compares bedrooms and floor area. Examples at 300 and 400 gpd need 900 and 1,050 gallons of conventional tank capacity; basin rules can change treatment requirements.
Read the tank record first. These conventional-system examples are design minimums, not local installed averages.
| Bedrooms and enclosed area | Design flow | Minimum effective tank |
|---|---|---|
| 2 bedrooms, 751–1,200 sq ft | 200 gpd | 900 gallons |
| 3 bedrooms, 1,201–2,250 sq ft | 300 gpd | 900 gallons |
| 4 bedrooms, 2,251–3,300 sq ft | 400 gpd | 1,050 gallons |
Heavy and rigid. Check seams, lids and shell condition.
Lighter. Proper support and fittings matter.
Lightweight. Approved installation and groundwater precautions matter.
Florida uses the greater bedroom or floor-area flow. Treatment equipment and field design must also meet the approved plan.
Confirm utility availability and the exact watershed. Northern Indian River Lagoon has a new-septic permit prohibition.
Soil layers, seasonal water, setbacks and space for the field shape the plan.
Compare conventional treatment where allowed with approved nitrogen-reducing options; a pump alone does not remove nitrogen.
Provide the floor plan, signed site plan, legal description and required soil data to DOH-Brevard.
Arrange required inspections, keep final records and follow any operating-permit and service-contract requirements.
Practical answers for Melbourne homes and businesses.
No. Sewer availability, basin restrictions, soil and local rules control. Northern Indian River Lagoon has a new-system permit prohibition.
No. Florida uses the greater flow from bedroom count or enclosed building area. Treatment approval and field design also matter.